A Mineral on How Easy It Can Be Strapped

Wiring MethodsWilliam (Bill) Burr

The CE Code is a comprehensive document. Sometimes it can seem quite daunting to quickly find the information you need. This series of articles provides a guide to help users find their way through this critical document. This is not intended to replace the notes in Appendix B or the explanations of individual requirements contained in the CEC Handbook, but will hopefully provide some help in navigating the code.In this article: Section 12 — Wiring Methods.

It should be noted that while many other sections of the code are commonly used by designers, installers and regulators, Section 12 is mostly used byelectricians, who must clearly understand all aspects of wiring, and by electrical inspectors, who audit compliance of the wiring methods with the code requirements. Electrical inspection authorities must always be consulted on specific issues related to wiring methods.

Section 12 is a general section and applies to all wiring installations except for
•    Class 2 circuits
•    community antenna distribution and radio and television circuits
•    opticalfibre cables
•    communication circuit conductors
•    conductors integral to factory-built equipment

That is, unless specified in the respective code sections covering those type of installations. We will discuss this later when dealing with Sections 16, 54, 56, and 60in future instalments.

The rules of this section may also be modified by the provisions of Section 32 — Fire alarm systems, Section 36 — High voltage installations or Section 45 — Emergency power supply, unit equipment exit signs and life safety systems.

Section 12 of the Code is divided into six parts:
•    General Requirements
•    Conductors
•    Raceways
•    Cablebus
•    Manufactured wiring systems
•    Installation of boxes, cabinets, outlets and terminal fittings

Generally the definitions in Section 0 apply throughout, but there are some special terminology definitions in the sub-section rules covering flat conductor cable type FCC.

In the General Requirements part, rules 12-010 to 12-020 apply specifically to locations where fire, mechanical, moisture or other environmental issues must be considered or locations where wiring may be prohibited, such as ducts and plenum chambers, underground installations, hoistways, lightning down conductors, entry of raceways and cables into buildings, and wiring under raised floors for data processing.

The Conductors part includes the rules applying to the installation of all types of conductors.It is divided into a general subdivision and individual subdivisions for each type of conductor.

In the General subdivision of Conductors,Rule 12-100 establishes that types of conductors must be chosen for their location with respect to moisture, corrosive action, temperature, degree of enclosure and mechanical protection as set out in Table 19. The Appendix B notes offer additional specifications on choosing the appropriate type of conductor.

Rules 12-102 to 12-120 provide general considerations for the installation of all conductors, such as:
•    the treatment of insulated conductors
•    flame test coverings
•    multi- and single-conductor cables
•    conductors in parallel
•    radii of bends in conductors
•    conductor joints and splices
•    treatment of the ends of insulated conductors
•    termination of conductors
•    termination and splicing of aluminum conductors
•    supporting of conductors

You will find, again, that extensive notes in Appendix B provide additional helpful information, including a diagram outlining configurations for installing parallel conductors.

The rest of the Conductor subdivision deals with the rules for specific types of conductors:
•    open wiring Rules 12-200 to 12-224 apply to single conductors run as open wiring (colloquially referred to as "knob and tube wiring")
•    exposed wiring on exteriors of buildings and between buildings on the same premises —Rules 12-302 to 12-318
•    barebusbars and risers —Rules 12-400
•    non-metallic-sheathed-cable: Rules 12-500 to 12-526 (NMSC)
•    armoured cable —Rules 12-600 to 12-618
•    mineral-insulated cable, aluminum-sheathed cable, and copper-sheathed cable —Rules 12-700 to 12-716
•    flat conductor cable Type FCC —Rules 12-800 to 12-824

The third part, Raceways, includes the rules applying to the installation of all types of raceways.It is divided into a general subdivision and subdivisions for each type of raceway.

The General subdivision,Rules 12-902 to 12-944, governs the installation of all
•    raceways and conductors run in raceways
•    types of conductors and cable suitable for use in raceways as per Table 19
•    conductors in raceways
•    protection of conductors at the ends of raceways
•    inserting conductors in raceways
•    conductors, in conduit and tubing
•    joints or splices within raceways
•    stranding of conductors, electrical continuity of raceways
•    mechanical continuity of raceways
•    junction of open wiring and raceways
•    entry of underground conduits into buildings
•    raceways installed underground or where moisture may accumulate
•    metal raceways in plaster
•    protection for raceways installed in concrete, cinder concrete, and cinder fill
•    raceways completely installed before conductors are installed
•    capping of unused raceways
•    maximum number of bends in raceways
•    metal raceways embedded in slabs, pavement or roadbeds

The rest of the Raceways part documents the rules for specific types of raceways:
•    rigid and flexible metal conduit:Rules 12-1000 to 12-1014
•    rigid PVC conduit: Rules 12-1100 to 12-1124
•    rigid types EB1 and DB2/ES2 PVC conduit: Rules 12-1150 to 12-1166
•    rigid RTRC conduit: Rules 12-1200 to 12-1220
•    liquid-tight flexible conduit: Rules 12-1300 to 12-1308
•    electrical metallic tubing: Rules 12-1400 to 12-1414
•    electrical non-metallic tubing: Rules 12-1500 to 12-1514
•    surface raceways: Rules 12-1600 to 12-1614
•    underfloor raceways: Rules 12-1700 to 12-1718
•    cellular floors: Rules 12-1800 to 12-1820
•    auxiliary gutters: Rules 12-1900 to 12-1904
•    busways and splitters: Rules 12-2000 to 12-2020
•    wireways: Rules 12-2100 to 12-2112
•    cable trays: Rules 12-2200 to 12-2210

The fourth part, Cablebus, includes the rules applying to the installation of cablebus as a complete system.Rules 12-2252 to 12-2260 include:
•    the use of Cablebus
•    methods of installation
•    connection to other wiring methods
•    provisions for bonding
•    ampacities of conductors in cablebus

The fifth part, Manufactured wiring systems, includes Rules 12-2500 and 12-2502 specifying the uses permitted, and Installation of Manufactured wiring systems

The sixth sub-section, Installations of boxes, cabinets, outlets, and terminals, includes Rules 12-3000 to 12-3036 that cover
•    outlet boxes
•    outlet box covers
•    terminal fittings
•    terminal fittings behind switchboards
•    boxes in concrete construction
•    outlet box supports, boxes, cabinets and fitting supports
•    accessibility of junction boxes, outlet boxes, cabinets and fittings
•    outlet boxes attached to existing plaster work
•    outlet boxes, etc., in damp places
•    entrance of conductors into boxes, cabinets and fittings
•    unused openings in boxes, cabinets, and fittings
•    extensions from existing outlets
•    multi-outlet assemblies
•    conductors in boxes, cabinets or fittings
•    wiring space in enclosures
•    maximum number of conductors in a box,
•    pull box or junction box sizes

 In the next installment we will be discussing Section 14 — Protection and control.

* The source for this series of articles is the Canadian Electrical Code, Part I, published by CSA

Read the rest of the instalments in the series:
Part 1: Guide to the CE Code, Part I – A Roadmap (Installment 1 in a Series)
Part 2:
A Road Map to the CE Code, Part I – Installment 2
Part 3: Guide to the Canadian Electrical Code, Part I – Installment 3
Part 4: A Road Map to the CE Code, Part 1 – Installment 4
Part 5: Guide to the Canadian Electrical Code, Part I — Installment 5
Part 6: Guide to the Canadian Electrical Code, Part I — Installment 6
Part 7: Guide to the Canadian Electrical Code, Part I — Installment 7
Part 8: Guide to the Canadian Electrical Code, Part I — Installment 8
Part 9:
Guide to the Canadian Electrical Code, Part I — Installment 9
Part 10: Guide to the Canadian Electrical Code, Part 1 - Installment 10
Part 11: Guide to the Canadian Electrical Code, Part 1 - Installment 11


William (Bill) Burr is the former Chair of the Canadian Advisory Council on Electrical Safety (CACES), former Director of Electrical and Elevator Safety for the Province of BC, and former Director of Electrical and Gas Standards Development and former Director of Conformity Assessment at CSA Group. Bill can be reached at Burr and Associates Consulting billburr@gmail.com.

Contractors! You Deserve Better.

Ledvance EIN Aug4 You Deserve Better July 2022Contractors! You Deserve Better | Win $2,000 Grand Prize from LEDVANCE, THE WORLD'S LEADING VERTICALLY INTEGRATED LIGHTING COMPANY

OFFERING SYLVANIA AND LEDVANCE BRANDED LIGHTING PRODUCTS IN CANADA

You deserve better and LEDVANCE wants to make sure you know it. Enter for a chance to be one of over 190 winners with the grand prize including $2000 and a SYLVANIA Work Light!

Read More


2021 Canadian Electrical Code Overview of Changes

EIN CSA Group Logo 2022 400CSA C22.1:21,Canadian Electrical Code, Part I contains many updates and changes that are potentially significant to electrical professionals. This online, self-guided course provides the key changes and impacts to the industry presented in an easy-to-follow format.

 Designed for professionals with a good working knowledge of the Code and who solely need the key changes including general updates or those made for clarification, safety, and new products and systems. Key changes due to Rule relocation or deletion are also noted.

This course may help save valuable time to help keep electrical projects safe and in compliance. This training is developed with input from a broad cross-section of electrical industry experts and with cooperation from all provinces, territories and several key jurisdictions across Canada.

Read More


Liteline Acquires Contraste Lighting

EIN Liteline CL 400

Liteline are very excited to announce that Liteline Corporation has acquired Contraste Lighting.

Founded in 1989, Contraste has had many market leading innovative product developments. Over the years, Contraste has become a well-known and respected Canadian lighting fixture manufacturer across North America.

Liteline is proud to be able to continue to market this iconic Canadian Lighting brand. Contraste will be merged with Liteline and provide the opportunity to expand our product offering in Canada and the United States.

Learn more about Liteline


Changing Scene

  • Prev

EIN Liteline logo 400

Liteline are very excited to announce that Liteline Corporation has acquired Contraste Lighting. ...

EIN EBH Vicotria 400

E.B. Horsman & Son (EBH) has announced their Victoria branch has moved to a new location as ...

EIN CBTU Logo 400

Canada's Building Trades Unions has been selected as an intermediary for the Apprenticeship Service ...

EIN NSAA logo 400

More skilled trades workers can seek certification in Nova Scotia with changes the Province is ...

EIN Procore logo 400

Procore Technologies, Inc. has announced it is working with Amazon Web Services (AWS) to ...

EIN Can logo 400

ECABC logo 400

The Electrical Contractors Association of BC (ECABC) has announced the impending departure of ...

EIN Government of Canada Logo 400

The Minister of Employment, Workforce Development and Disability Inclusion, Carla Qualtrough was at ...

EIN CAF Logo 2022 400

The launch of the Apprenticeship Service stands to help overcome financial barriers employers face ...

LDS NETCO CNMIE 400

The National Electrical Trade Council (NETCO) is pleased to announce that they will be rolling out ...

OmniCable Joins ETIM North America

Omnicable joins ETIMETIM North America announced that OmniCable has joined the product classification standards organization. Headquartered in West Chester, PA, OmniCable has 24 locations throughout North America, and also owns Houston Wire & Cable (HWC). The company partners with many electrical manufacturers and only sells to distributors.

According to John Dean, Director of Marketing & E-Commerce, OmniCable/HWC, "The wire and cable industry is often called commodities, but there are very distinct features and attributes for the different products our manufacturers produce.

Read More


Atkore Inc. Announces Acquisition of United Poly Systems

Atkore United Poly SystemsAtkore Inc. announced that it has acquired United Poly Systems, a manufacturer of High Density Polyethylene (HDPE) pressure pipe and conduit, primarily serving telecom, water infrastructure, renewables, and energy markets.

"We are pleased to complete the acquisition of United Poly Systems, which strengthens Atkore's product portfolio, expands our manufacturing capacity and further enables us to meet HDPE customers' needs," stated John Pregenzer, President of Atkore's Electrical business. "HDPE pipe and conduit is a growing market that is expected to benefit from U.S. infrastructure legislation, and United Poly Systems is a great addition to Atkore. We welcome these employees and look forward to working together to continue to serve and support our customers."

Read More


Canadian Electrical Contractor Discussion Group: Can You Count the Deficiencies?

EIN CECD 400Have you ever been called to fix the work of a 'handyman'?

"Was supposedly done by a"certified ' electrician....told the homeowner that he got a $266 permit....no record at TSBC. Can you count the deficiencies?"

"There is a second panel change in the triplex also.......even more deficiencies. Think the guy was a glorified handyman. Ones not obvious: 240 BB heat hooked up 120....drier on 2p20....range on 2p50....water heater fed with 2c14 Bx on 2p15."

Go HERE to join the discussion


Grimard is more competitive and produces estimates 3X faster with Procore

Procore

When the pandemic lockdowns started in March of 2020, Grimard (an electrical contractor) had to decide whether to shut down its operations entirely or implement a new platform with people who were now freely available for work. Once they implemented Procore, they found a way to efficiently communicate with stakeholders and offer full transparency in terms of project costs and planning. It also allowed Grimard to utilize historical data to make project estimates more accurate. Grimard was able to streamline its bidding process, which made it more attractive to potential clients and helped the business grow.

Read More




RenuWell Pilot Projects Transform Inactive Wellsites to Generate Solar Energy

Iron+EarthThe RenuWell Project partners are excited to announce the groundbreaking of two pilot sites located near Taber, Alberta. These pilot sites are the first of their kind to repurpose inactive oil and gas infrastructure as a foundation for renewable energy development and job creation.

When operating, the solar projects will generate 2,030 MWh annually – enough electricity to power 280 average Alberta households or irrigate 11,700 acres of farmland for an average year. This is roughly equivalent to $200,000 in electricity sales per year with 1,100  tCO2e savings in GHG emissions. Over a 25-year lifespan, the projects will generate 50,750 MWh, with GHG emission savings of 28,420 tCO2e.

Read More


Product News

  • Prev

EIN DCC 11 EV 400

DCC-11, manufactured by Thermolec, is an energy management system designed to allow the connection ...

EIN Leviton EV 400

Evr-Green Level 2 Electric Vehicle Charging Station, 30 A, 208/240 VAC, 7.2kW Output, NEMA Type 3R ...

EIN Mersen HelioProtection Fuses HP15M 400

Mersen has announced the extension of the Gen2 of its HelioProtection series of HP15M solar fuses. ...

EIN Klein Tools Knee Pads 400

Klein Tools introduces Lightweight and Heavy Duty Knee Pad sleeves, both of which feature a compact ...

EIN Nuheat 240 400

Nuheat cable is an electric radiant floor heating system designed to allow installers to customize ...

EIN IDEAL Belt 400

Consisting of 6 component parts, and 2 bundles, the Pro Series Tool Belt System is a fully ...

EIN M18 Hawg 400

The M18 FUEL™ HOLE HAWG® Right Angle Drill w/ QUIK-LOK™ Kit delivers the next generation of ...

EIN SATCO STARFISH Floodlight Camera 400

SATCO STARFISH LED Smart Security Floodlight & Camera has been designed to trigger based on ...

EIN LAPP ÖLFLEX HEAT 260 400

ÖLFLEX® HEAT 260 SC - PTFE single core, robust, chemical resistant and space-saving, for use in ...

EIN ABB Combiner 400

Since the line's introduction, ABB Power Conversion's Power Express combiners have helped provide ...



Ericson Reintroduces Industrial String Lights & SL Stringlight Series

Ericson String LightsEricson announces upgraded versions of their extremely capable line of Industrial String Lights and SL, LED Stringlights. These new and updated products have several key features important when safe, code compliant lighting for industrial workspace is necessary.

Infinitely capable, these ruggedly built products have several industry leading & exclusive features including:

Industrial String Lights:

  • A United States Navy Specification since before WWII, they're time and application tested...

Read More


Intermatic Introduces New Installer-Focused Pool and Spa Solutions

Intermatic Pool and Spa SolutionIntermatic Incorporated announced its new P40000 Series Load Centers, a set of next-generation panels for pool-only applications, as well as its new PE24GVA 24-Volt Valve Actuator, an easy-to-install valve actuator that allows for tool-free cam adjustments. Both solutions remove obstacles for pool service professionals while delivering lasting performance.

"Intermatic load centers and valve actuators have been the preferred choice of pool professionals for more than 30 years," says Brian Lamberty, product marketing manager at Intermatic. "The PE24GVA and P40000 Series build on that tradition, helping pool professionals streamline service calls while setting the standard for quality and performance."

Read More


Emerson Safety Device Prohibits Unauthorized Access to High-Voltage Electrical Connections

Emerson HV SafetyThe Occupational Safety and Health Administration (OSHA) estimates 350 employees are killed annually in electrocution accidents, which roughly equals one fatality per day. In the face of these dangers, OSHA officials and industry safety consultants alike recommend eliminating potential hazards on work sites, rather than simply relying on contractors or employees to follow safety guidelines.

To help safeguard employees from electrocution, Emerson has launched its Appleton™ Powertite™ Lock Collar, a device that fastens over plug and connector connections and is secured with a padlock, preventing unauthorized personal from disconnecting the cable connection once in place.

Read More


Peers & Profiles

  • Prev

EIN Watts Word logo 400

Watt's the Word is a recently launched Electrical Industry Podcast hosted by Zack Hartle and ...

EIN ECAO KLine 400

Allana Kellett-Jamieson loves working in the electrical sector and is proud of the great focus ...

Eric Deschenes 400

As the head of ABB Canada's electrification business unit, Éric Deschênes is no newcomer to the ...

EIN Pullen IBEW 400

Karen Pullen knows what it's like to be the only woman on a construction site, and as a proud ...

CEW 7 Signify 1 400

As of February 2021, Martin Stephenson is the new President and CEO of Signify Canada.   ...

Kerith Richards

This past July, Kerith Richards, who has worked for Service Wire Company for the last seven years, ...

EngWorks

EngWorks was formed in 2004 as an electrical engineering and consulting firm by Allan Bozek, "After ...

EIN Mercury Eric 400

Headquartered in Concord, Ontario, Mercury Lighting services national retail, ...

CEW 9 Carolina Gallo 400

Among the recipients of the 2021 Clean50 Awards announced last month is Carolina Gallo, Vice ...

Sarah Silverstein

Sarah Silverstein is a principal with Liteline along side her two brothers Mark and Daniel. ...

Copper $US Dollar price per pound

greerustract.blogspot.com

Source: https://www.electricalindustry.ca/latest-news/1750-guide-to-the-canadian-electrical-code-part-i-instalment-7

0 Response to "A Mineral on How Easy It Can Be Strapped"

Enregistrer un commentaire

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel